Advance
TEMPERATURE DISPLAY (as detected by probes)
1.
Ensure that the control panel is not locked and that no procedure is in progress.
2.
Press the DOWN arrow for 4 seconds: the display will show the first probeavailable.
3.
Select the correct probe using the UP and DOWN arrows.
4.
Press the SET key.
This table shows the codes for each of theprobes.
Label
Displayed temperature
Pb1
Cabinet temperature
Pb2
Evaporator temperature
To exit the procedure, press the SET key for 60 seconds or do not operate for 60 seconds.
Thenpress the ON/OFF key.
Note: if the evaporator probe is not present, the Pb2 code will not be displayed.
TEMPERATURE ALARMS
This is a list of alarms shown by thiscabinet.
CODE
Description
AL
Low Temperature Alarm
AH
High Temperature Alarm
Id
Open Door Alarm
COH
High Condensation Warning
CSd
High Condensation Alarm
dFd
Defrost Alarm
Alarm recording can only be done while the cabinet is turned on.
When the cause of the alarm is no longer present, the cabinet will return to normal operation.
ACCESS TO ALARM HISTORY
1.
Press the DOWN button for 2 seconds to show the first code
2.
Press and release the UP button or select LS by pressing the DOWN button
3.
Press and release the SET button: one of the codes above will
beshown To select an alarm, press the UP button till AH is shown.
To show alarm information, press and release the SET key (the flashing HACCP LED willstop).
Low temperature alarm.
(This alarm is saved in the alarm log.)
High temperature alarm.
(This alarm is saved in the alarm log.)
Door alarm, if the door remains open or is not properly closed.
It shows that the temperature detected by the condenser sensor has
reached the first alarm value.
Indicates that the temperature detected in the condenser sensor has
reached the second alarm value.
This code is shown in the display if the defrosting has been interrupted
at the maximum time allowed for a defrosting
EN
Explanation
8