4.9
Technical specifications
4.9.1
Level controllers
Parameter
General specifications
Dimensions housing (W x H x D)
Weight
Response delay
Indication of probe signals
Indication of output signal
Outputs
Connections for PTC thermistor probes 2
Ambient conditions
Ambient temperature operation
Ambient temperature storage
Supply voltage
Electrical data
Nominal power
Mains fuse
Type of attachment of non-detachable
cords
Breaking capacity output relay
Protection class (EN 60730)
Degree of protection (60529)
Pollution degree
Rated impulse voltage
Type of design
Product description
Value
53 x 113 x 108 mm
550 g
Less than 2 s
2 yellow LEDs
1 green LED
1 output relay (changeover contact)
-10 ... 55 °C
-10 ... 60 °C
AC 230 V
50 ... 60 Hz
Max. 12 VA
M 100 mA (5 x 20 mm)
Type M
Max. 250 V, 2 A
II
IP 30
II
2500 V
Automatic electric control
RG 210
EN
16