The Digital Relay Unit 12090010 SAR-GTWIN is dedicated to GTwin system and allows to activate electric
loads by means of a 230Vac 5A contact relay with commands (events) sent by users with apartment stations,
call stations or switchboard.
The main uses are:
•
Driveway passages opening.
•
Stairs lights lighting.
•
Electric loads activation/deactivation.
Device main features are:
•
Monostable operating mode with activation time adjustable from 1 second to 16 minutes, or toggle mode.
•
Activation with system events (4 maximum, with competence areas jumper to C or Q) programmable by
the installer.
•
Possibility of activation with user events (32 max. with competence areas jumper to S), programmable
by the installer.
•
A remote button can be connected for activation.
A - User code dip-switch used to identify the decoder in the system
B - Competence area jumpers:
S = only the device used to acquire the event
C = all devices of the riser column used to acquire the event
Q = any system device
C - Switch mode jumper
M = monostable
T = toggle
D - Programming button and led
E - Trimmer used to adjust the activation timer in monostable mode (M)
F - Remote button connection terminal pins (PC)
G - Line connection terminal pins (LINE)
H - Terminal pins of relay contact used to activate electric loads (C-NC-NA)
INSTALLATION
The Digital Relay Unit can be installed in a service panel on DIN rail (6 18mm DIN modules) or wall mounted
with screws and screw anchors (not provided).
For installation, follow general installation instructions of GTwin system in the 50122345 TRIP TGTWIN
SYSTEM MANUAL.
Please observe also the following rules:
•
The Digital Relay Unit can be installed only using the distributor 12070104 D4L-GTWIN; connect it to one
of the 4 distributor outputs.
•
In-out connection is not allowed.
10
C
B
A
ON
CODE
NA
NC
C
H
S C Q
M T
PROG
TIMER
GTwin
12090010
LINE
UNIDAD RELE SAR-GTWIN
D
E
PC
F
G
50122456 DS551209-003