0970 RingMount
/ Redundant RingMount
Options for Securing the Weigh Modules
5
»
BOLT
the weigh module to a concrete floor:
OR
Bolt top plate
Tank Leg
to tank leg
Concrete/Foundation
Mounting plate surface must be level to 1/2° or
All weigh modules must be in the same plane within 3mm (1/8").
- OR -
BOLT
the weigh module to a metal plate:
Installation Tips and Precautions
• Never extend or cut the load cell's cable length.
• Avoid moisture and dust.
• Ensure voltage stability (use regulated power supply).
• Avoid overload and shock.
• Ensure good grounding.
• For hazardous area installations in Europe, refer to enclosed
instructions (30104376 / 175389R).
Weigh Module » Installation Guide
- OR -
LEVEL AND GROUT
Shim as
needed
Bolt base plate
Bolt top plate
Expansion
to tank leg
anchor
1mm (1/16")
Levelling
100mm (6")
adjustment nut
Tapped holes
Through holes
- OR -
the weigh module:
Shim as
Tank Leg
needed
Bolt base plate
to foundation
Nonshrink
Epoxy Grout
Concrete/Foundation
Anchor Insert
J-Bolt
Download Installation Guide:
Installation Guide is available in:
English, German, Spanish, French,
Italian, Dutch, Portuguese, Swedish,
Danish, Norwegian, Polish, Czech,
Hungarian, Russian,Turkish
www.mt.com/ind-downloads-ringmount
WELD
the weigh module:
• Remove load cell from weigh module before welding.
• Ground wire of welder must be as close to the weld seam as
possible to ensure proper grounding.
Contact authorized METTLER TOLEDO technician for proper
removal and re-installation of load cells.
Weld:
3/8" (9 mm) Fillet
1" (25 mm) long
3" (75 mm) centers
Tank Leg
Contact authorized METTLER TOLEDO service
technician to activate the weigh modules for startup
and calibration.