WARNING
The minimum vertical distance to combustible material
above the cooking top is 24" (610 mm), provided the
overhead construction does not extend 15" (381 mm) from
the rear wall.
NOTE: If installing a range hood or microwave hood
combination above the cooking surface, follow the
range hood or microwave hood combination installation
instructions for dimensional clearances above the cooktop
surface.
Cabinet and counter cutout:
A
D
E
B
A
19 5/8 ± 1/8" (499 ± 3mm)
B
10 5/8" ± 1/8" (270 ± 3mm)
C
4 1/8" ± 1/8" (105 ± 3mm)
D
15/16" (23mm) Max.
E
1 9/16" (40mm) Max.

Cooktop Installation

Once the cabinet has been prepared according to the
presented dimensions and the gas line is in place.
1.
Unpack the cooktop, and lift it away from the packaging.
Remove all packing materials.
2. Lift the top glass
cover assembly at the rear side, push it
back and then pull to remove it.(Fig.1)(Fig.2)
Fig. 1
CCD-0006069 Rev: 07-09-22
C
Separator Shelf
Fig. 2
3. Slide the cooktop into the cabinet opening. Verify that the
cooktop is level from side to side and front to rear (Fig.3).
Fig. 3
4. Attach the cooktop into the cabinet on both the left and
right sides using four self-tapping screws on both left and
right (2 screws each side).(Fig.4)
Fig. 4

Gas Connection

1.
Connect a certified gas supply line with a 3/8" Flare
Female connection to the cooktop. Tighten according to
appropriate RV and gas codes using two wrenches. Hold
regulator in place while tightening gas connection. (Fig 5)
Fig. 5
IMPORTANT: Leave adequate space around the gas supply
pipe in case of bend or damage during installation. Make sure
the gas supply pipe is not contacting any moving parts after
installed. Be sure all openings in the cabinet around the gas
- 5 -