1. Vent hole. It is necessary that all submersible sump, effluent, and sewage
pumps capable of handling various sizes of solid waste be of the bottom
intake design to reduce clogging and seal failures. If a check valve is
incorporated in the installation, a vent hole (approx.
drilled in the discharge pipe below the check valve and pit cover to purge
the unit of trapped air. Trapped air is caused by agitation and/or a dry basin.
Vent hole should be checked periodically for clogging. The pump has a
vent hole located in the pump housing opposite the float, adjacent to a
housing lug, but an additional vent hole is recommended. If you choose
not to drill a vent hole, be sure the pump case and impeller is covered with
liquid before connecting the pipe to the check valve and no inlet carries
air to the pump intake. NOTE: THE HOLE MUST ALSO BE BELOW THE
BASIN COVER AND CLEANED PERIODICALLY. Water stream will be
visible from this hole during pump run periods.
2. Pump should be checked frequently for debris and/or build-up which may
interfere with the float "on" or "off" position. Repair and service should be
performed by Zoeller Pump Company Authorized Service Station only.
3. Dewatering and effluent sump pumps are not designed for use in pits
handling raw sewage.
4. Non-automatic pumps with external-level controls are recommended for
septic tank effluent applications.
Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used
and maintained, for a period of five years from the date of purchase.
Proof of purchase is required. Parts that fail within the warranty period,
that inspections determine to be defective in material or workmanship,
will be repaired, replaced or remanufactured at Manufacturer's option,
provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No
allowance will be made for shipping charges, damages, labor or other
charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any
material or product that has been disassembled without prior approval
of Manufacturer, subjected to misuse, misapplication, neglect, alteration,
accident or act of nature; that has not been installed, operated or
maintained in accordance with Manufacturer's installation instructions;
that has been exposed to outside substances including but not limited
to the following: sand, gravel, cement, mud, tar, hydrocarbons,
hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive
or corrosive substances, wash towels or feminine sanitary products,
etc. in all pumping applications. The warranty set out in the paragraph
above is in lieu of all other warranties expressed or implied; and we
LED light-up plug may dim or extinguish after approximately 5 years. This does not mean the pump has failed. Although the LED
light-up plug is attached to the pump, the LED light works independently from the pump. If this happens, visually inspect the pump
to verify it is working properly. This occurrence does not mean pump replacement under warranty. If you have any questions, please
contact Zoeller Product Support at 1-800-928-7867 or +1-502-978-2731.
In those instances where damages are incurred as a result of an alleged pump failure,
the Homeowner must retain possession of the pump for investigation purposes.
CAUTION
5. Maximum operating temperature for standard model pumps must not
exceed 130 °F (54 °C).
6. Do not operate a pump in an application where the Total Dynamic Head is
/
" [5 mm]) must be
3
less than the minimum Total Dynamic Head listed on the Pump Performance
16
Curve.
7. The tank is to be vented in accordance with local plumbing code. Pumps
must be installed in accordance with the National Electrical Code and all
applicable local codes and ordinances. Pumps are not to be installed in
locations classified as hazardous in accordance with National Electrical
Code, ANSI/NFPA 70.
8. According to the state of California (Prop 65), this product contains chemicals
known to the state of California to cause cancer and birth defects or other
reproductive harm.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are
tested to UL Standard UL778. CSA Certified pumps are certified to CSA
Standard C22.2 No. 108.
Limited Warranty
do not authorize any representative or other person to assume for us
any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky
40211, Attention: Customer Service Department to obtain any needed
repair or replacement of part(s) or additional information pertaining
to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR
SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR
BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND
ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO
THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.