K2 Pumps SPC03301K Manuel Du Propriétaire page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRIMARY PUMP TROUBLESHOOTING
Symptom
Pump won't start or run
Pump starts and stops
too often
Pump won't shut off
Pump operates but
delivers little or no water
BATTERY BACKUP SYSTEM TROUBLESHOOTING
Pump will not start
or run
Motor hums but pump won't run
Pump runs but pumps very little
or no water
For Professional Technical Support call 1-844-242-2475
Possible Cause(s)
No power.
The impeller is blocked.
The float switch failed.
The motor failed.
Float obstructed
Faulty float switch
Defective float switch
Restricted discharge
(obstacle or ice in piping)
Float obstructed
Restricted intake screen
Low line voltage
Something caught in
impeller
Worn or defective parts or
plugged impeller
Check all the wiring connections.
Check for a low or defective battery.
Check that the float switch is free to move
up and down.
Press the circuit breaker reset button on the control panel.
Check for low or defective battery.
The Positive (+) and negative (–) pump wires are reversed.
Disconnect them and reconnect correctly.
Check for a low or defective battery.
Check for an obstruction in the discharge pipe.
Corrective Action
Reset GFCI switch/Reset the breaker/Secure
the plug/Clean the plug prongs.
Remove the debris around the impeller.
Replace the float switch.
Replace the pump.
Remove obstruction.
Replace float switch.
Replace float switch.
Remove pump and clean pump and piping.
Remove obstruction.
Remove the pump and clean the intake screen
and the impeller.
If voltage under recommended minimum,
check size of wiring from main switch on
property. If OK, contact power company or
hydro authority.
Remove the pump and clean out the impeller.
Clean impeller if plugged; otherwise replace
pump.
9

Publicité

Table des Matières
loading

Table des Matières