Safety Instructions - K2 Pumps SPC03301K Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PERFORMANCE
Performance - PSP
GPH at total feet of lift
Series
HP
Primary
1/3
Pump
Performance - BSP
Series
Backup Pump
Electrical & Switch Specifications
Series
Primary Pump
Backup Pump

SAFETY INSTRUCTIONS

1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water
before disconnect the power.
5.
Release all pressure and drain all water from the system before servicing any component.
6.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7.
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension
cord to power this pump is not permitted.
8.
Wear safety goggles at all times when working with pumps.
9.
This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The
3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle.
Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong
receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and
ordinances. All wiring should be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
2
0
5
4000
3720
GPH at total feet of lift
HP
0
1/16
1800
Motor Full Load
HP
1/3
1/16
GPH at total feet of lift
10
15
3400
3060
5
10
1400
900
Amps
6.1
NA
For Professional Technical Support call 1-844-242-2475