11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE ADAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
15. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in
keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in
premature failure.
16. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand,
and debris. Disconnect the pump from the power supply before inspecting.
17. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all
Occupational Safety and Health Administration (OSHA) guidelines must be followed.
18. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset
itself once the motor cools down and an acceptable temperature has been reached. The pump may start
unexpectedly if it is plugged in.
19. Ensure the electrical power source is adequate for the requirements of the pump.
20. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris
may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump
problems and remedies.

PRE-INSTALLATION

GENERAL INFORMATION

The Battery Backup Combo Kit is pre-plumbed up to the hose and clamp assembly. The system includes the primary
sump pump (PSP), backup sump pump (BSP) assembly, and vertical float switch. The unit is equipped with two check
valves - one for the primary pump and one for the backup pump.
The battery backup pump is not a substitute for your primary sump pump. It is designed to temporarily backup your
primary sump pump during a power outage or other problem which prevents normal operation of the primary pump. Do
not use this system to pump flammable liquids or chemicals. Pump clear sump water only with this pump. For
residential use only.
Keep the battery charger dry and protected from damage. This system is designed to work with either a sealed
lead-acid AGM battery or a flooded lead-acid battery. Use of a true Gel Cell (often confused for AGM) or a standard
automotive battery with this charger is not recommended. An automotive battery may require charging after only 1-2
hours of continuous use, and the repeated charging cycles may cause early plate failure in the battery.
Specifications
Maximum vertical pumping distance
Power supply required
Liquid Temp. Range
Individual Branch Circuit Required (min.)
Discharge:
For Professional Technical Support call 1-844-242-2475
Primary Sump Pump
Backup Sump Pump
Hose & Clamp Assembly
Minimum pit diameter
Minimum depth
13.35 feet (3.4M)
115V, 60 HZ
12V DC Battery
32° F to 90° F
15 Amps
1-1/2" connect
12"
18"
3