Configuration
Configuring the detector
To ensure the detector can detect the system receiver, register the detector by entering the 11-
digit serial code or perform the following steps for assigning the RF:
1.
Set the system receiver to "Learn" mode.
2.
If not already performed, connect the battery.
3.
Send an allocation message by pressing the tamper button for at least 3 seconds (or
connect the detector to the mounting bracket) until the system receiver indicates
that it has received the allocation message.
Upon successful registration, the detector's green LED indicator makes 4 short blinks.
Visual / Audible Indicators
If the red LED indicator (see Figure 10) flashes once every 30 seconds, the detector is
functioning normally.
If the red LED indicator flashes constantly and repetitive beeps are heard, the detector is
reacting to a fire alarm (primary or secondary).
The LED indicator flashes and a short beep is heard once every 30 seconds to indicate low
battery or trouble condition.
If a fire alarm is activated, press the cover up firmly (see Testing the detector) to silence the
alarm and temporarily disable (for approx. 10 minutes) the alarm activation.
Detector parameters
The following detector parameters can be defined from the system receiver:
Parameter
Operational Mode:
Supervision Time:
* = default
See your system receiver's installation / configuration manual for more information about
defining detector parameters.
Option
Smoke only*, Heat only or Smoke and Heat
1-255 (15 min*)
10