Please read carefully
before installation and
use.
To the Fitter:
Check that the product is
suitable for the intended
application, follow instruc-
tions and ensure operating
instructions are passed on to
the user.
To the User:
Before use, read the follow-
ing instructions carefully.
Application:
This bilge pump is designed
to exhaust standing water.
Output capacity depends on
installation conditions and
pumping rate. Users should
be aware that capacity may
not be sufficient to cope with
rapid influx of water.
If it is intended for use for
any other purpose or with
any other liquid, it is the
users' responsibility to
ensure that the pump is suit-
able for the intended use
and, in particular, that the
materials are fully compati-
ble with the liquids to be
used. With all applications,
it is important that a system
of safe working practice is
applied to installation, use
and maintenance.
INSTALLATION
The Compac 50 is a covered
Compac 50
diaphragm pump, designed
specifically for low profile
installation below deck or
thru bulkhead. The pump
chamber complete with
inlet/outlet hose connec-
tions, can be rotated
through 360° (Fig. 1) allow -
ing complete flexibility in
the choice of flow direction
relative to the handle posi-
ton.
Rotation of body can be
in either direction
Fig. 1
To change direction of flow:
a) slacken the clamping
ring screws
b) rotate the pump body to
the desired postions
c) tighten the clamping
screws, (this can be adjust-
ed even after installation).
Inlet/Outlet Options:
There are 4 possible hose
directions for both inlet and
outlet. These can be com-
bined to give 16 flow orien-
tations (see Fig.2)
BP0350
Fig. 2
To Change Inlet/Outlet
Positions:
a) remove the 4 self-
tapping screws from base of
inlet/outlet.
b) reposition inlet/outlet
c) replace the 4 self-
tapping screws and tighten.
Mounting the Pump
The Whale Compac 50
comes with deckplate. The
hole positions are square,
allowing a choice of pumps
stroke direction, relative to
the orientation of the deck-
plate.
1. Using deck plate as tem-
plate, mark off and drill 4 x
¼" (6 mm) holes and cut out
a 33/8" (86 mm) hole, which
should be central to the 4 x
¼" (6 mm) holes. Round off
the edge of the hole to allow
easy mounting of the gaiter.
2. Minimum deck thickness
is 3/16" (5 mm). Deck can
be reinforced up to a maxi-
mum of 5/8" (15 mm) by
using a backing plate.
3. Position the pump under-