Télécharger Imprimer la page

American Standard Studio-S 4803410 Instructions D'installation page 3

Publicité

Les langues disponibles

Les langues disponibles

5
CHECK CONNECTIONS FOR LEAKS
• Move HANDLE into "off" position.
• Turn on water supplies and check connections for leaks.
• Operate HANDLE up and down, left and right to flush
water lines thoroughly.
• Operate HAND SPRAY and check connections for leaks.
6
SERVICE
If Faucet Drips, Proceed As Follows:
• Turn VALVE to OFF position.
• Operate HANDLE several times from OFF to ON position. Do not apply excessive force.
Reduced Flow:
• Clean out spray head screen.
• Clean out cartridge.
Clogged CARTRIDGE outlets or inlets may
cause reduced flow.
To clean, first turn off water supply then:
• Loosen HANDLE SCREW (1) and remove
HANDLE (2).
• Unthread ESCUTCHEON CAP (3),
SNAP RING (4).
• Lift CARTRIDGE (5) off MANIFOLD (6) and
remove CARTRIDGE SEALS (7).
• Clean MANIFOLD (6), CARTRIDGE (5)
ports and SEALS (7).
• Place SEALS (7) into CARTRIDGE PORTS (5a).
• Place CARTRIDGE (5) onto MANIFOLD (6).
• Replace ESCUTCHEON CAP (3), SNAP RING (4),
HANDLE (2), tighten HANDLE SCREW (1).
7
CARE INSTRUCTIONS:
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CHECK CONNECTIONS
FOR LEAKS
7
- 3 -
5a
5
2
6
4
3
1
M985013 (3/19)