Operation and Setting

6.1

Possible Settings and Operating Modes

The BOD 26K is ready to operate after applying the operating voltage.
However, the following settings can be made if necessary:
· Set the switching point or switching window
· Scale the analogue output
· Set the operating mode (Speed Mode / Averaging Mode )
· Set the switching type (N.O./N.C)
· Reset the sensor to the factory state
· Laser off and measured value hold (via electrical connection)
· Lock buttons „S" and „T" (via electrical connection)
6.2

Factory State:

· Switching output:
Switching output is active when the object is in the operating range and reliably detected. Switching type = N.O.
· Analogue output (4...20 mA): 4 mA = end of operating range, 20 mA = beginning of operating range
· Operating mode = speed mode (shortest response time)
· Operation = free running (normal mode)
6.3
Indicators and Setting Elements
The BOD 26 K is set with the buttons S and T.
Set button:
Toggle
button:
Conf
and
Exit
The LEDs indicate the selected settings.
LED Colour
BA
ZA
BA
ZA
Q
QA
A
OK
V
Q
N
FS
C
QA
Av
OK
Nc
FS
Illustr. 6
15501560
No. 852592 E Edition 1111; Replaces edition 0901; Subject to modification
Change or confirm setting or teach in switching point.
Select setting, jumps one setting forward.
Pressing both buttons simultaneously causes:
3 s Conf
=> activate set mode
1x press Exit
=> data are saved and the setting mode exited
Use
Green
Operating indicator
Red
Status indicator
(only active in the Set mode)
Yellow
Indicates status of output Q
Yellow
Indicates status of output QA
Green
Signals operating mode
(speed/averaging)
Green
Stability indicator (good target)
Green
Signals switching type N.O./
N.C.for output Q
Green
Factory Setting
(only active in Set mode)
Description
On: ready for operation (Run mode)
Flashing: Set mode is active
Lights: selected setting is active
Lights: switching output active
Lights: object is within the set 0% and
100 % range
Lights: operation set with averaging
Lights: object safely detected and in the
operating range
Lights: switching type N.C. set
Lights: factory setting selected