Electrical Requirements - U.s.a. Only - Maytag MES5752BAW Instructions D'installation

Masquer les pouces Voir aussi pour MES5752BAW:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
H
F
A. 13" (33.0 cm) upper
cabinet depth
B. 30" (76.2 cm) min.
opening width
C. For minimum clearance
to the top of the cooktop,
see NOTE.
D. 23¹⁄₄" (59.1 cm) opening
depth
E. 30" (76.2 cm) min.
opening width
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
4
A
B
C
D
E
I
G
F. Junction box - 5.5" (14.0 cm) min.
from either cabinet, 10" (25.4 cm)
max. from floor
Outlet must be flush.
Nothing located in shaded
area can extend more than
2" (5.1 cm) from wall or range will
not slide all the way back.
G. Cabinet door or hinge should not
extend into cutout.
H. 18" (45.7 cm) minimum clearance
I. 3" (7.6 cm) minimum clearance to
cabinet wall

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge is in accordance
with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
I
outlet installed by a qualified electrician.
This range is manufactured with the neutral terminal connected
to the cabinet. Use a 3-wire, UL listed, 40-amp power supply
cord (pigtail); or if local codes do not permit ground through the
neutral, use a 4-wire power supply cord rated at 250 volts,
40 amps and investigated for use with ranges.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. (The model/serial number rating plate is located on the
oven frame behind the storage drawer panel.)
When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz,
AC only electrical supply is available, a 50-amp maximum
circuit protection is required (or, if specified on the model/
serial rating plate, when a 4-wire or 3-wire single phase
120/208 volt 60 Hz, AC only electrical supply is available, a
40- or 50-amp maximum circuit protection is required), fused
on both sides of the line.
A time-delay fuse or circuit breaker is recommended.
The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible or nonmetallic
sheathed, copper or aluminum cable. See "Electrical
Connection."
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
Wire sizes and connections must conform with the rating of
the range (40 amps).
The wiring diagram is located on the underside of the storage
drawer or below the warming drawer in a clear plastic bag.
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471