X-Boost; Emergency Power Supply (Eps) - EcoFlow RIVER Pro Manuel D'utilisation

Masquer les pouces Voir aussi pour RIVER Pro:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57

3.8 X-Boost

To avoid operation failure due to overload protection, the X-Boost feature will be automatically
enabled when the total output exceeds the rated output power, which enables the product to
power high wattage appliances at the rated output power.
X-Boost Tips:
1. X-Boost is enabled by default; you can enable or disable it in the EcoFlow App.
2. X-Boost is not available when the AC output is turned on in a recharging state (in bypass mode)
and when X-Boost is disabled.
3. X-Boost is not applicable for all electrical appliances; it's incompatible with appliances with strict
voltage requirements. Appliances with voltage protection (such as precise instruments) are not
supported. X-Boost mode is more suitable for heating devices. Please conduct your own tests with
your devices with X-Boost enabled.

3.9 Emergency Power Supply (EPS)

The product supports EPS. When you connect the grid power to the AC Input Port of the product
through an AC Charging cable, you can power electrical devices through the AC Output Sockets (AC
power will come from the grid and not the power station in this situation). In case of a sudden blackout,
the product can automatically switch to the battery powered supply mode within 30ms. As a basic
UPS function, this function does not support 0ms switching. Please do not connect the product to
any device that requires 0ms UPS, such as data servers and workstations. Please test and confirm
the compatibility before using the product. We recommend that you only charge one device at a
time and avoid using multiple ones at the same time to avoid overload protection. EcoFlow takes no
responsibilities for any device failures or data losses caused by failures to follow instructions.
9

Publicité

Table des Matières
loading

Table des Matières