Analog reverse loop

The analog reverse loop reverses the main track polarity instead of the loop polarity. For an automatic
operation however a few details have to be observed. A seperate power supply is required to power the
module (14 – 24 V DC). A minimum driving voltage of 5 Volts is required to ensure a safe sensor operation.
Additional diodes must not be used. The reverse loop must always be operated in the same direction.
Caution: If you use the Z21
deactivated.
N
20
20
8010797920 XI_2018.indd 20
multi LOOP in analogue mode, the short circuit detection is to be
®
08.11.2018 12:03:31