6. Adjust the Valve - Left Handle
CAUTION: Risk of property damage. The water supply
must be shut off before performing these steps.
CAUTION: Risk of property damage. At the maximum
valve body extension, a detent will be encountered. To avoid
leakage, do not extend the valve beyond this detent. If the
valve needs to be extended further, install deep rough-in kit
1107027. If the valve needs to be recessed further, install
shallow rough-in kit 1107026.
IMPORTANT! Perform these steps when the handle will be located
on the left side of the spout.
Shut off the water supply.
Remove the plaster guard/retaining ring tool.
Position a bucket at the spout outlet, then open the valve handle
to relieve water pressure. Leave the handle open.
Using the tool, loosen the threaded retaining ring until the valve
body disengages from the mixer valve.
Kohler Co.
All manuals and user guides at all-guides.com
Spring Plunger
O-Rings
180˚
Plaster Guard/Tool
9
Valve Body
Retaining Ring
1095311-2-J