Adjust the Valve - Left Handle (cont.)
Pull out the valve body. The plaster guard/retaining ring tool can
be threaded onto the valve body to get a better grip when pulling
it out.
Rotate the valve body 180 degrees from the original position. This
allows the handle to move up when turning the water on.
Verify the o-rings on both the valve body and the mixer valve are
undamaged.
Verify the spring plunger is installed and is flush with the surface
of the valve body.
Reinstall the valve body into the mixer valve until fully seated.
Using a straight edge, adjust and hold the valve body flush with
the finished wall.
NOTE: A screwdriver inserted through the holes in the plaster
guard/retaining ring tool can serve as a handle.
With the valve body flush with the finished wall, retighten the
retaining ring with the tool.
Close the valve handle.
Turn on the water supply and check that the valve is functioning
properly.
1095311-2-J
All manuals and user guides at all-guides.com
10
Kohler Co.