OPERATION – HOW TO CHARGE
PLEASE READ CAREFULLY BEFORE USING
Attention
Suitable for all type of 12V/24V Lead Acid-, Gel-, AGM- and Deep Cycle batteries
1. Turn the control dial to "OFF"
2. Preparing the battery
Firstly remove the caps from each cell and check that the level of the liquid is sufficient in
each cell. If it is below the recommended level, top up with de-ionized or distilled water.
Note
Under no circumstances should tap water be used.
The cell caps should not be replaced until charging is complete. This allows any gases
formed during charging to escape. It is inevitable that some minor escape of acid will occur
during charging.
For permanently sealed battery, it is not necessary to carry out the above checks.
3. Connection
• Please make sure that the RFC4500 is not connected to AC power.
• First connect the positive charging lead (red) to the positive terminal post of the
battery (marked P or +). After that connect the negative charging lead (black) to the
negative terminal post of the battery (marked N or -) or the vehicle frame. It is
important to ensure that both DC clamps are making a good contact with their
respective terminal posts.
• At last connect the charger's AC power cable to the mains with an adequate ground.
4. Charging
Turn the control dial to the appropriate charging setting and take note of the LED indicators
and display codes.
Charge recommendation:
Control Dial Setting
12V 10A
12V 30A
24V 8A
24V 15A
The current indicator will display the charge supplied to the battery in amps
Recommended application
12V batteries , 50-300AH
12V batteries , 150-600AH
24V batteries , 50-200AH
24V batteries , 60-300AH
6