Section 2

Remote Condenser/Line Set Installation

Remote Single
Ice Machine
Circuit Condenser
K1000
K1350
K1800
*Line Set
Discharge Line
RTK
1/2" (1.27 cm)
RLK
1/2" (1.27 cm)
Air Temperature Around the Condenser
Minimum
-20°F (-29°C)
Important
Remote systems are only approved and warranted as a
complete new package. Warranty on the refrigeration
system will be void if a new ice machine head section
is connected to pre-existing (used) tubing or remote
condensers.
Part Number 000012545 Rev 03 07/22
Line Set*
RTK-20-R410A
KC1000
RTK-35-R410A
RTK-50-R410A
RLK-20-R410A
KC1350
RLK-35-R410A
RLK-50-R410A
RLK-20-R410A
KC1350
RLK-35-R410A
RLK-50-R410A
Liquid Line
5/16" (.79 cm)
3/8" (.95 cm)
Maximum
120°F (49°C)

REMOTE ICE MACHINE REFRIGERANT CHARGE

Each remote ice machine ships from the factory with a
refrigerant charge appropriate for installation with line
sets of up to 50' (15 m). The serial tag on the ice machine
indicates the refrigerant charge.
Additional refrigerant may be required for installations
using line sets between 50' and 100' (15-30 m) long. If
additional refrigerant is required, refer to the chart below
for the correct amount to be added.
Ice Machine
K1000
K1350
K1800
Important
EPA CERTIFIED TECHNICIANS
If remote line set length is between 50' and 100'
(15 and 30 m), add additional refrigerant to the
nameplate charge. Refer to the table below for the
model being worked on.
Tubing length: _________________________________
Refrigerant added to nameplate: __________________
New total refrigerant charge: _____________________
Potential Personal Injury Situation
The ice machine contains refrigerant charge. Installation
of the line sets must be performed by a properly trained
and EPA certified refrigeration technician aware of
the dangers of dealing with refrigerant charged
equipment.
Installation
Refrigerant to be added for
50'-100' Line Sets
2 lbs (907g)
2 lbs (907g)
2 lbs (907g)
Warning
15