Section 2

Installation Check List

Is the Ice Machine level?
Have all of the electrical and water connections
been made?
Has the supply voltage been tested and checked
against the rating on the nameplate?
Is there proper clearance around the ice machine for air
circulation?
Is the ice machine grounded and polarity correct?
Has the ice machine been installed where ambient
temperatures will remain in the range of 35° - 110°F
(1.6° - 43.3°C)?
Has the ice machine been installed where the incoming
water temperature will remain in the range of 35° - 90°F
(1.6° - 32.2°C)?
Is there a separate drain for the potable water,
bin and water-cooled condenser?
Are the ice machine and bin drains vented?
Are all refrigerant lines free from contact with
other components?
Are all electrical leads free from contact with
refrigeration lines and moving equipment?
Has the owner/operator been instructed
regarding maintenance and the use of our De-
scaler and Sanitizer?
Has the owner/operator completed the
warranty registration card?
Has the ice machine and bin been sanitized?
Is the ice thickness set correctly? (Refer to
Operational Checks to check/set the correct ice
bridge thickness).
Part Number 000012545 Rev 03 07/22

Additional Checks for Remote Models

Does the remote condenser fan operate properly
after start-up?
Has the remote condenser been located where
ambient temperatures will remain in the range of -20° -
120°F (-29 - 49°C).
Is the line set routed properly?
Are both refrigeration lines to remote condenser run so
they do not lay in water and are properly insulated?

Before Starting the Ice Machine

All ice machines are factory-operated and adjusted before
shipment. Normally, new installations do not require any
adjustment.
To ensure proper operation, follow the Operational Checks
in Section 3 of this manual. Starting the ice machine and
completing the Operational Checks are the responsibilities
of the owner/operator.
Adjustments and maintenance procedures outlined in this
manual are not covered by the warranty.
Potential Personal Injury Situation
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified from
that of original manufactured specifications.
Installation
Warning
19

Publicité

Table des Matières
loading

Table des Matières