8. Make sure the sprayer is earthed (grounded). All sprayers are
equipped with a earthing (grounding) cable (1). Clip the end
of the grounding cable to a true earth ground.
9. Strain all paints with a nylon strainer to ensure trouble free
operation and freedom from frequent cleaning of the inlet
screen and gun filter.
10. Make sure the spray area is well ventilated to prevent
hazardous operation with volatile solvents or exhaust fumes.
If lacquer or other flammable materials are to be
sprayed, ALWAyS locate the compressor outside the
immediate spraying area. Failure to do so may cause
an explosion.
11. Locate the compressor outside the immediate spraying area
to avoid clogged air intake of the compressor with overspray.
SuperCoat
GB
4.2
The automatic lubricator (Fig. 10, item 1) provides lubrication to the
air that is being delivered to the system. It is set at the factory for the
correct injection rate and should not be adjusted until the reservior
needs to be refilled with MotorCare™ (0533922) lubricant. Check the
1
level through the openings (2) in the side of the air motor shroud.
After refilling the reservoir, the automatic lubricator will need
adjusting. Turn the adjusting screw (1) clockwise to increase the
MotorCare™ (0533922) injection rate and counterclockwise to
decrease it.
1
2
Check the injection rate by observing the flow through the openings
in the side of the air motor shroud.
• The proper flow rate is 1 drop of MotorCare™ (0533922) per
minute.
• In cold weather when icing may occur, increase the injection
rate.
9

Automatic Lubricator