Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal fi lters are required on top of its standard mesh
fi lter set. Order according to its part number below. The standard mesh fi lters are intended to capture residue
from cooking and the optional charcoal fi lters help to purify fumes exhausted from cooking for recirculation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal fi lters, brackets and air diverter plate.
Hood Models
Part No.
ZRM-E36BS
ZRC-00RM
ZRM-E42BS
ZRC-01RM
1. Purchase recirculating kit per the part number above
2. Secure air diverter plate to top support frame (FIG. B) Open sides of air
diverter plate should face left and right to direct air through the louver holes
located on the top duct cover. Run 6" ducting from top of hood and secure
to air diverter plate.
3. Remove aluminum mesh fi lters from hood. Secure charcoal fi lter brackets
to the hood body behind each mesh fi lter using the screws included with
the recirculating kit. Clip charcoal fi lters onto each charcoal fi lter bracket.
(FIG. C)
4. Re-Install mesh fi lters. For more details refer to manual included
with recirculating kit.
5. Charcoal fi lters must be replaced after every 120 hours of use (or
approximately every 3 to 4 months based on an average of 1 - 2 hrs.
of daily cooking time).
Charcoal Filter Replacements
Hood Model
ZRM-E36BS
ZRM-E42BS
DO NOT WASH CHARCOAL FILTERS. Charcoal fi lters may need
to be changed more often depending on cooking habits.
All manuals and user guides at all-guides.com