en
Fault resolution
Always disconnect the vacuum
cleaner from the power supply be-
fore attempting to rectify a fault.
Switch off at the wall socket and un-
plug it.
Cleaning the pre-filter (dia. 30 + 31)
The pre-filter is located at the rear of the
vacuum cleaner.
This should be cleaned if it is obviously
dirty.
Remove the dust container.
Release the handle of the pre-filter
and remove the pre-filter.
Rinse the pre-filter under cold running
water.
Do not use washing-up liquid!
Do not use any sharp or pointed ob-
jects!
Dry the pre-filter carefully!
Replace the dry filter in the dust con-
tainer and lock the handle.
Replace the dust container in the va-
cuum cleaner.
Cleaning the fine dust filter
manually (dia. 32 - 37)
Allow a drying time of 24 hours.
Remove the dust container.
Release the fine dust container in the
direction of the arrow and remove it.
Run a little water into the opening at
the top of the fine dust container.
Gently shake the fine dust container
back and forth.
42
This will rinse out the dust.
Shake to empty the water out.
Release the top so that the marking is
pointing to the symbol.
Carefully lift the fine dust filter up-
wards and out of the fine dust con-
tainer.
Rinse the outside of the fine dust filter
under cold running water.
Do not clean the inside of the
fine dust filter!
Do not use washing-up liquid!
Do not use any sharp or pointed ob-
jects and do not brush the fine dust
filter!
After cleaning, allow the fine dust fil-
ter to dry for a minimum of 24 hours!
Clean the fine dust filter container
with water and mild washing-up li-
quid.
Dry the fine dust filter container thor-
oughly.
Insert the dry fine dust filter into the
dry fine dust container so that the
marking is pointing to the symbol.
Lock the top into place so that the
marking is pointing to the symbol.
Replace the fine dust container in the
vacuum cleaner and lock it into place.
Replace the dust container in the va-
cuum cleaner.