DANGER
WARNING
CAUTION
NOTICE
CAUTION
•
Read the operating instructions completely before
starting up and follow the safety instructions.
•
Keep the operating instructions in a place where it can
be accessed by everyone.
•
Ensure that only trained staff work with the device.
•
Follow the safety instructions, guidelines, occupation-
al health, safety and accident prevention regulations.
•
Install the stand on a flat, stable, clean, non-slip, dry
and fire-resistant surface.
The adjustment screw (3)
NOTICE
can be used to compensate
for unevenness on the set-
up plate. Use the lock nut
to
screw.
•
Prior to each use, always check the stand, stirrer/dis-
perser and accessories for damage. Never use dam-
aged parts.
Check the mounting posi-
DANGER
tion of the stirrer/disperser
to avoid the danger of the
unit tipping over.
Observe the maximum per-
DANGER
missible load-bearing capac-
ity (see "Technical data").
•
You must also follow the safety instructions contained
in the operating instructions for the stirrer or disperser.
•
Check that the stirrer/disperser is installed correctly
before use and at regular intervals.
•
Because the options for combining products, tools,
stirring vessel, trial set-up and medium are nearly end-
less, user safety cannot be ensured simply with design
requirements on the part of the product. For this rea-
12
All manuals and user guides at all-guides.com
Explication of warning symbols
Indicates an imminently hazardous situation, which, if not avoided, will result in death, seri-
ous injury.
Indicates a potentially hazardous situation, which, if not avoided, can result in death, serious
injury.
Indicates a potentially hazardous situation, which, if not avoided, can result in injury.
Indicates practices which, if not avoided, can result in equipment damage.
Indicates crushing risk of fingers/hand.
Safety instructions
lock
the
adjustment
son, it may become necessary for users to take other
precautionary safety measures. For example, glass
apparatus or other stirring vessels that are sensitive
to mechanical stress can be damaged or shattered by
an imbalance, increasing the speed too quickly or too
little distance between the stirring tool and the stir-
ring vessel. Users can sustain serious injury from glass
breakage or from the freely-rotating stirrer tool.
Telescopic stand R 2723
Please pay attention to the
DANGER
dangerous
equipment in Fig. 2.
Serious danger of crushing!
CAUTION
When adjusting the height
of the movable stand rod,
ensure that nothing be-
comes caught between the
devices or other objects at-
tached to the bracket, e.g.
the lower end stop or lip of
the container.
The stand rod (1) must be
WARNING
held in place when loose-
ning the knurled screw (Fig.
2.2) (avoid rapid increases).
Always store the stand in a
NOTICE
relaxed state.
parts
of
the