31.
The device must not be connected to the outlet other
than wall-mounted socket, do not use a multiple
outlet adapter or multiple sockets.
32.
In case the power supply is cut off from the
appliance it is necessary to wait about 5 minutes
before reconnecting the appliance to the electricity
in order to avoid damage to the appliance.
Failure
to
follow
safety
recommendations
instructions may result in serious injuries or death!
TECHNICAL DATA
Product name
Chest freezer
Model
RCFZ-
RCFZ-
RCFZ-
RCFZ-
98
152
197
252
Rated input power
52
78
82
85
[W]
Rated current [A]
0,48
0,5
0,5
0,63
Power
0,465
0,541
0,604
0,681
consumption
[kWh/24h]
Energy class
A+
Power supply [V]/
230~/50
Frequency [Hz]
Refrigerant
R600a
R600a
R600a
R600a
/ 54g
/ 62g
/ 65g
/ 67g
Temperature [°C]
-12~-28
Net volume [l]
98
152
197
252
Freezing capacity
5
8
10
12
[kg/24h]
Electric shock
I
protection class
Emitted noise level
44dB
Temperature rise
31,5
38
43
49
time [h]
AEC (Annual
170
197
220
248
Energy
Consumption)
[kWh/year]
EEI (energy
41,3
40,6
41,2
40,6
efficiency ratio)
Climate class*
T
Weight [kg]
28
32
38
43
Height adjustment
Yes
Basket / shelves
1 basket
Lock
Yes
Product name
Freezer
Chest freezer
Model
RCFZ-
RCFZ-
RCFZ-
RCFZ-
W88L
560
459
368
10
Rated input
195
135
135
power [W]
Rated current
1,5
1,31
1,31
[A]
Power
2,8
1,112
0,970
consumption
and
[kWh/24h]
Energy class
-
A+
Power supply
230~/50
[V]/
Frequency [Hz]
Refrigerant
R134a
R600a
R600a
/80g
/114g
/110g
Temperature
-7~-24
-12~-28
[°C]
Net volume [l]
88
560
459
Freezing
-
26
21
capacity
[kg/24h]
Electric shock
I
protection class
Emitted noise
46dB
50dB
level
Temperature
-
55
53
rise time [h]
AEC (Annual
-
406
354
Energy
Consumption)
[kWh/year]
EEI (energy
-
41,4
41,9
efficiency ratio)
Climate class*
4
T
Weight [kg]
55
79
72
Height
Yes
adjustment
Basket/ shelves
3
4
4
shelves
basket
basket
Lock
Yes
*Climate class T means that the ambient temperature of
the appliance should be within the range from +16 to 43°C.
SCOPE OF THE APPLICATION
Freezers
RCFZ-98,
RCFZ-152,
RCFZ-197,
RCFZ-560, RCFZ-459, RCFZ-368 are intended for use in
the household. The model RCFZ-W88L is intended for
commercial use.
Freezers are used to store and freeze food.
The user is liable for any damage resulting from non-
intended use of the device!
BERORE THE FIRST USE
Upon receipt of the goods, check the packaging for defects
and open the packaging if there are no damages.
Rev. 23.11.2017
If the packaging is damaged, please contact your transport
110
company and distributor within 3 days, and document the
damages as detailed as possible. Do not turn the package
upside down! When transporting the package, please
1,2
ensure that it is kept horizontal and stable.
0,843
DISPOSING OF THE PACKAGING
Please keep all packaging materials (cardboard, plastic
tapes and Styrofoam), so that in case of a problem, the
device can be sent back to the service centre in accurate
condition!
GENERAL HINTS FOR THE USER
The appliance must be cleaned after unpacking and before
its connection to the power supply network. Once the
R600a
freezer has reached the set temperature, it can be filled
/93g
with (frozen food, and in case of intention to put fresh food
it is necessary to comply with the parameter informing
about the maximum weight of frozen food during 24 hours
and the instructions for freezing of fresh food contained
in this document). It is forbidden to fill the freezer with
368
warm liquids and food and any food products put into the
17
appliance should be covered. Food products and drinks
should be stored in sealed airtight containers. In order to
ensure adequate air circulation inside the appliance it is
recommended to place products be in such a manner in
order to maintain distance between them.
If the door is opened too often, there is increased energy
consumption, which could lead to possible damage.
Always close the door of the appliance when it is not in use.
Do not use screwdrivers or other metal tools in order
to remove ice layers that are formed on the walls of the
51
appliance during its use.
After closing the cover, do not open it again suddenly and
307
with use of force, the gasket located around the closure
of the appliance chamber can hinder to open it for about
1 or 2 minutes. After this time, the appliance should open
normally.
In case of you do not use the appliance for a longer time,
41,6
in order to save electricity, it is necessary to disconnect the
cleaned appliance from the electricity, to clean and leave
the door open in order to prevent gathering of unpleasant
odours inside the appliance.
56
DEVICE DESCRIPTION
RCFZ-W88L
7
3
basket
6
5
4
RCFZ-252,
3
Rev. 23.11.2017
8
1.
housing
2.
adjustable feet
3.
lock
4.
rack of shelves
5.
glazed door
6.
shelves
7.
internal lighting
8.
control panel
Models: RCFZ-98, RCFZ-152, RCFZ-197, RCFZ-252,
RCFZ-560, RCFZ-459, RCFZ-368
A
B
E
D
R
G
M N O P
E
C
H
I
F
S
A.
cover
B.
cover gasket
C.
internal lighting
1
D.
housing
E.
chamber for frozen products
F.
ventilation grid
G.
control panel
H.
parting
I.
chamber for products intended for freezing
2
K.
hanging basket
L.
compressor chamber
M.
compressor
N.
desiccant filter
O.
fan
P.
capillary tube
S.
water drain
L