s
Shunt Trip
Disparador de Apertura
Déclencheur à émission de courant
Installation Instructions / Instructivo de Instalación
Hazardous Voltage.
Hazardous Voltage.
Will cause death or serious injury.
Will cause death or serious injury.
Turn off and lock out all power supplying this device before
Turn off and lock out all power supplying this device before
working on this device.
working on this device.
Replace all covers before power supplying this device is
Replace all covers before power supplying this device is
turned on.
turned on.
Use only with Siemens certified components.
Utilizar únicamente con componentes certificados de Siemens.
A utiliser uniquement avec les composants certifiés Siemens.
s
STRER240
110-240V
Application Ratings
[ Intensidad de la aplicación ]
Catalog
Number
Voltage U
[ Número De
[ Voltaje ]
Catálogo
( U
o )
24 - 60
STREM60D
24 - 60
STRER240
110 - 240
(Suitable for use in
ground fault
protection
applications)
110 - 125
STREV600
380 - 600
8 0 7 8 9 4 A 0 3
Tensión peligrosa.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Puede causar la muerte o lesiones graves.
Desenergice totalmente antes de instalar o darle servicio.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
energizar el interruptor.
Shunt Trip
110-125V
~
50/60Hz, 1.5A Max Inrush
Suitable for Ground Fault
Sensing Element
Supply
Voltage
o
Frequency
[ Fuente de
[ Frecuencia ]
Voltaje ]
( U
24
50 – 60 Hz
48
60
24
DC
48
60
110
120
127
50 – 60 Hz
208
220
240
110
DC
120
125
380
415
440
50 – 60 Hz
480
525
550
600
STRER240 = 110-125V
STREM60D = 24 - 60V
STREV600 = 380-600V
STRER240 = 110-240V
STREM60D = 24-60V
YELLOW
[AMARILLO]
Electrical Operating Ratings (Nominal Values)
[ Grados de operacion electrica (Valores Nominales) ]
Minimum Operating
Voltage
[ Voltaje minimo de
operación ]
)
s
18
18
60
82
285
1 / 4
Item:
For Use With Frame EG
Para Usar Con Caja Base EG
Tension dangereuse.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Danger de mort ou risque de blessures graves.
Couper l'alimentation de l'appareil et barrer avant de
Couper l'alimentation de l'appareil et barrer avant de
travailler.
travailler.
Remplacez touts les couverts avant que
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
l'approvisionnement de pouvoir soit alimenté.
V
~
V
50 / 60 HZ
a
ST
Inrush Current
[ Entrada de corriente
repentina ]
(A)
1.7
2.9
3.5
5.0
9.9
12.0
.75
.77
.92
1.3
1.4
1.5
0.9
1.0
1.0
1.1
1.3
1.3
1.3
1.6
1.6
1.8
IL01219036EH04
STREM60D
STREV600
STRER240
WHITE
[BLANCA]
VA
[ VA ]
41
139
210
120
475
720
83
92
117
270
308
360
99
120
121
418
540
572
624
840
880
1080