ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly aware, and in respect of the normative
regulations
Protection against parts under tension must be ensured after the building.
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
CONNECTION OF THE HOB
For the various kinds of connection, use the brass bridges which are in the box next the
terminal.
Caution!
- Connect always the earth wire.
- Respect the connection diagram.
- This device is intended for a supply of 230 V ~ 50/60 Hz
- The connection box is located underneath at the back of the hob casing. To open the cover
use a medium screwdriver. Place it in the slits and open the cover.
Country
Mains
230V~ 50/60Hz
FR-NL
PT-GB
400V~ 50/60Hz
( * ) calculated with the simultaneous factor following standard EN 60 335-2-6/1990
Important
It is forbidden to extent or to shorten the liaison wires areas of the cooking zones ( 5,6,7,8; see
page 28) Only the control panel (C) may be extended (Order our only lengthens ref A10506/0).
Monophase 230V~1P+N:
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminate "earth", the neutral N to terminal 3 or 4, the Phase L to one of
the terminals 1 or 2.
Biphase 400V~2P+N:
Put a bridge between terminal 3 and 4.
Attach the earth to the terminate "earth", the neutral N to terminal 3 or 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
nd
between 3 and 4.
30
Protection
Cable
calibre
H 05 VV - F
25 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F