Delicately pull the Ethernet cable (05) until the
RJ45 connector (06) is completely inserted in the
compartment of the mobile connector body.
After inserting the cage and the gasket, tighten the
sealing nut (07).
Pay attention to the fixing. Tightening
torque (sealing nut 07): from 0.9Nm up to
1Nm.
06
Fig. 9
Fig. 10
Complete assembly.
Connect the mobile connector on the fixed
connector and tighten the ring nut.
6.6 Mobile connectors cabling
(power supply, I/O)
Use of cables with the following characteristics is
highly recommended:
• Cable diameter: from 6mm (0.24in) up to 9mm
(0.35in) (gasket with small hole), or from 9mm
(0.35in) up to 12mm (0.47in) (gasket with large
hole).
• For the type of cable, refer to the PTZ camera
manual.
Cable the mobile connector by operating as follows.
Choose the type of gasket suitable for the cable (Fig.
11, page 5).
MNVKUEBP4_2222_EN
07
05
Fig. 11
Insert the cable using the sealing nut (01), the gasket
(02) and the body of the connector (03).
03
Fig. 12
6.6.1 4-pole connector
For 4-pole connectors, loosen the screws on the
terminals on the front of the connector, insert the
conductors and fasten them tightening the screws.
Pay attention to the fixing. Tightening
torque: from 0.3Nm up to 0.35Nm.
Fig. 13
4-pole connector.
4-POLE CONNECTOR
Colour
Pin number
Yellow-Green
GND
Blue
1
Red
2
White
3
Tab. 2