It is essential to wax the heater plate after cleaning.
You can switch directly to the waxing program by pressing the temperature selection but-
ton on the right or exit the cleaning program by pressing and holding the button for
at least 3 seconds.
Starting the waxing program
Press and hold the button for at least 3 seconds.
2 temperature selection buttons which do not take the form of temperature dots (e.g., )
are displayed.
To start the waxing program, press the temperature selection button on the right.
The Rotary Iron will switch to the waxing program.
To deactivate the waxing program, press the button and then keep the button
pressed for at least 3 seconds.
When the Rotary Iron has reached a temperature of 176°F (80°C), the button begins to
flash. The waxing program is now ready to begin.
Press the flashing button to start the waxing program.
The heater plate can then be waxed using the waxing cloth.
Once waxing has been successfully carried out in the waxing program for a period lasting
at least 40 seconds, the maintenance interval for prompting the cleaning and waxing of
the heater plate (= red display symbol ) will be reset.
Using the waxing cloth and ironing wax
Sprinkle some ironing wax into the pocket of the waxing cloth.
Use the ironing wax sparingly to prevent the ironing cloth around the roller from becoming
too smooth.
en - Cleaning and care
176°F (80°C)
is shown in the display.
33