AquaScape ULTRAKLEAR 1000 Mode D'emploi page 8

Masquer les pouces Voir aussi pour ULTRAKLEAR 1000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. If replacing or removing the quartz sleeve remove the
threaded plastic collar at the base of the quartz sleeve and
remove the quartz sleeve.
CHANGING THE UV BULB
1. Grip the base of the UV bulb and pull it free from the
4-pronged socket
8
2. Replace UV bulb & quartz sleeve in the reverse order they
were removed.
WARNING: Do not touch UV bulb with bare
hands as the oil from skin will reduce the bulbs
performance and lifespan.
Use a clean tissue to wipe off any dirt or smudges on
the bulb and on the quartz sleeve. Also, make sure there
is no moisture inside the quartz sleeve or on the bulb prior
to reassembly.
3. To reinstall the ballast slide the quartz sleeve into the
UltraKlear
housing. Make sure to line up ballast flange
®
with the matching flange shape on the UltraKlear
housing.
4. Push ballast into the outer fixture tube and rotate
clockwise to lock it into position. Push the latch tab back
into place to lock the ballast in position.
®

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ultraklear 2500Ultraklear 5000950369503795038

Table des Matières