8.
ATTACH 8" ROUND ADAPTER AND DAMPER TO ROUGH-IN PLATE
(P6 INTERIOR BLOWER ONLY)
Attach transition to P6 blower rough-in plate.
Use metal foil duct tape to make all joints secure
and air-tight.
9. INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL BLOWERS)
Run power cable to installation location. Refer
to the instructions included with the selected
blower rough-in plate (sold separately) for details
on installing the rough-in plate. Attach blower
plate to the studs at the inside, top or back of
hood with 4 no.10-32 nuts, provided. Install the
rough-in plate so that the wiring box is located
on the right side as you are facing the hood.
For ducting through back of hood, remove
existing plate from inside back of hood and
attach it to inside top of hood to cover hole.
Secure to threaded studs with same 4 nuts.
For ducting through top of hood, existing plate remains in place on inside back of hood.
Connect ducting to adapter/damper or rough-in plate as you are installing the rough-in plate. Use metal
foil duct tape to make all joints secure and air-tight.
10. CONNECT THE WIRING (ALL BLOWERS)
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance
with all applicable codes and standards. Before connecting wires, switch power off at service
panel and lock service disconnecting means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover.
HO0196
B
P
LOWER
LATE
HD0048
WARNING
!
8
N
.10-32
O
NUTS
(2
)
PER SIDE