Installation guide
Wire position sensor
DST X800
ELECTRICAL CONNECTIONS
SINGLE VERSION
M12 x 1, 4-pin
Male connector
CONNECTIONS
1. + SUPPLY
2. GROUND
3. OUTPUT
4. n.c.
M12 x 1, 5-pin
Male connector
CONNECTIONS
1. + SUPPLY
2. n.c.
3. GROUND
4. OUTPUT
5. n.c.
HALF-REDUNDANT VERSION
M12 x 1, 5-pin
Male connector
CAN CONNECTIONS
1.GROUND
2. + SUPPLY
3. GROUND
4. CAN-H
5. CAN-L
REDUNDANT VERSION
M12 x 1, 8-pin
Male connector
CONNECTIONS
1. + SUPPLY 1
2. GROUND 1
3. OUTPUT 1
4. n.c.
5. + SUPPLY 2
6. GROUND 2.
7. OUTPUT 2
8. n.c.
SINGLE/REDUNDANT/HALF-REDUNDANT VERSION
M12 x 1, 8-pin
Female connector
WARNINGS
Release of spring under tension can result in injury.
Uncontrolled cable retraction can break off cable fixing.
Broken fixing and cable can result in injury.
Cable must not be oiled or lubricated.
Do not drag cable along objects,
Cable travel should be axial to cable outlet.
Use of the transducer outside the specifications are not suitable for the unit
and can cause damages to the unit, with risk of personal injury.
© Danfoss | DCS (im) | 2019.04
© Danfoss | DCS (im) | 2019.04
CAN CONNECTIONS
1. + SUUPLY
2. GROUND
3. CAN-H
4. CAN-L
CAN CONNECTIONS
1. n.c.
2. + SUPPLY
3. GROUND
4. CAN-H
5. CAN-L
CAN CONNECTIONS
1. + SUPPLY 1
2. GROUND 1
3. CAN-H 1
4. CAN-L 1
5. + SUPPLY 2
6. GROUND 2
7. CAN-H 2
8. CAN-L 2
M12 x 1, 8-pin
Male connector
CAN CONNECTIONS
1. GROUND
2. + SUPPLY
3. GROUND
4. CAN-H
5. CAN-L
DST X800
WIRE POSITION
SENSOR (CONTACTLESS)
Danfoss A/S 6430 Nordborg Denmark
www.danfoss.com
MOUNTING AND POSSIBLE CONFIGURATIONS
•
Do not open sensor
•
Do not exceed maximum operating voltage
•
Do not travel over range
•
Do not let snap the cable
•
Do not damage/snap/crack the cable
•
Special attention during mounting and operation of metal
cable and sensor
ATTENTION
For safety reasons, never screw off
the 8 screw of the rear body, shown
at the photo and marked with the X
WARNINGS AND SAFETY
Although all of the information in this manual has
been carefully checked, Danfoss A/S assumes no
liability regarding the presence of any errors or regarding
damage to property and/or harm to individuals due to any improper use
of this manual. Danfoss A/S also reserves the right to make changes to the
contents and form of this manual and to the characteristics of the devices
illustrated at any time and without prior warning.
The installation of the devices illustrated in the manual must be carried out by
qualified technicians in compliance with the laws and standards in force and
in agreement with the instructions contained in the manual.
LOAD CONDITIONS
+0.5Vdc...+4.5Vdc output (powered at +10..36VDC) and 0..10VDC output
(powered at +11..36VDC): apply a load resistance >100Kohm
4..20mA output (powered at < + 15..36VDC): maximum allowed load re-
sistance is 200 ohm
4..20mA output (powered at > + 15..36VDC): maximum allowed load re-
sistance is 500 ohm
Danfoss A/S products with the "CE" mark are manufactured according with
the Community Directives and the related National
Legislation of concepition:
- 2011/65/EU Restriction of the use of certain hazardous substances
(RoHS)
- 2014/30/EU Electromagnetic Compatibility (EMC)
- 2001/95/EC General product safety
and that the following (parts/articles of ) harmonized standards and
regulation have been applied:
- EN 50581:2012 Technical documentation for the assessment of electri
cal and electronic products with respect to the restriction of hazardous
substances
- EN 61326-1: 2013 Electrical equipment for measurement, control
and laboratory use - EMC requirements - Part 1:
General requirements
- EN 61326-2-3: 2013 Electrical equipment for measurement, control and
laboratory use - EMC requirements - Part 2-3:
Particular requirements
Test configuration, operational conditions and perfromance creteria for
transducers with integrated or remote signal conditioning.
AN30144864079901-000101 | IC.PD.P20.FA.2Q | 1