Installation guide
Rotary sensor without shaft
DST X520
ROTATION DIRECTION
AMP VERSION
Zero angular
position of 0 °
The output increases
for versions CCW
A
Ref
CW Output
A
0.5Vdc Output
Zero angular
B
position of 0 °
C
4.5Vdc Output
Ex: 098G1500
SINGLE- ± 90°- supply 7Vdc - output 0.5..4.5V - clockwise CW
Vout = 2.5 V
Angular position 0°
ELECTRICAL CONNECTIONS
AMP VERSION
AMP Superseal 6-pole 282108-1 connector
CONNECTIONS
1. GROUND 1
2. + SUPPLY 1
3. OUTPUT 1
4. GROUND 2
Reference magnet
5. + SUPPLY 2
6. OUTPUT 2
CABLE VERSION
6 wires 18 AWG 1.65 mm OD
Reference magnet
To ensure the degree of protection IPX9K the connector must be coupled
with AMP 282600-1female connector.
© Danfoss | DCS (im) | 2019.09
CABLE VERSION
The output increases
for versions CW
A
CCW Output
4.5Vdc Output
Zero angular
position of 0 °
0.5Vdc Output
Angular position 90°
Vout = 4.5 V
CAN CONNECTIONS
1. OV (GND)
2. +Vs (+9 ... +36 Vdc)
3. NC
4. NC
5. CAN-L
6. CAN-H
CAN CONNECTIONS
CONNECTIONS
1. OV (GND)
Black. GROUND 1
2. +Vs (+9 ... +36 Vdc)
Red. + SUPPLY 1
3. NC
Yellow. OUTPUT 1
4. NC
Green. GROUND 2
5. CAN-L
Blue. + SUPPLY 2
6. CAN-H
White. OUTPUT 2
DST X520
HALL-EFFECT SIGLE-TURN
ROTARY SENSOR WITH-
OUT SHAFT
Danfoss A/S 6430 Nordborg Denmark
www.danfoss.com
WARNINGS AND SAFETY
Although all of the information in this manual has
been carefully checked, Danfoss A/S assumes no
liability regarding the presence of any errors or regarding
damage to property and/or harm to individuals due to any improper use
of this manual. Danfoss A/S also reserves the right to make changes to the
contents and form of this manual and to the characteristics of the devices
illustrated at any time and without prior warning.
The installation of the devices illustrated in the manual must be carried out by
qualified technicians in compliance with the laws and standards in force and
in agreement with the instructions contained in the manual.
The system should be only used in accordance with
the expected protection.
The sensor must be used in accordance with the environmental
features and performance of the instrument.
LOAD CONDITIONS
+0.5Vdc...+4.5 Vdc output with power +9...+36Vdc and +0..10Vdc output
with power +11..36Vdc: it is recommended a load resistance > 100 KΩ
+0.5Vdc...+4.5 Vdc output with power +5 Vdc: it is recommended a load
resistance > 10 KΩ
+4...20 mA output with power < + 15..36Vdc: the maximum load resist-
ance is admissible 200Ω
+4...20 mA output with power > + 15..36Vdc: the maximum load resist-
ance is admissible 500Ω
MAGNETS
•
Magnet should NOT be incoporated in a ferromagnetic housing
(Holder)
•
Magnet should NOT be installed in close contact with a surface of
ferromagnetic material
•
If the magnet is incoporated in a housing (holder) of ferromagnetic
material or is installed in close contact with a surface of ferromag-
netic material the magnetic field is reduced
•
If the magnetic field is reduced the Air Gap value is no longer guar-
anteed up to 7 mm and working useful distance magnet-sensor is
reduced at <5 mm
•
If the application does not allow to use a material for the magnet
bearing surface is necessary to raise the magnet of at least 1 cm
•
To raise the magnet of at least 1 cm from the forromagnetic surface
we recommend to use NON ferromagnetic screws or spacers
MOUNTING
Mount the sensor using M4 screws in nonmagnetic
stainless steel: eg AISI 316 or brass (not included).
The maximum torque amounts to 2.5Nm.
•
It is recommended to use M12 female connectors with a
key interface, in order to mount with specified torque us-
ing a torque spanner.
•
In harsh environment we recommend to use tread seal-
ing liquid
Danfoss A/S with the "CE" mark are manufactured according with
the Community Directives and the related National Legislation of
concepition:
- 2011/65/EU Restriction of the use of certain hazardous
substances (RoHS)
- 2014/30/EU Electromagnetic Compatibility (EMC)
- 2001/95/EC General product safety
AN30144540778801-000301 | IC.PI.P20.BC.2Q | 1