Installation guide
Inclination sensor
DST X710
TILT DIRECTION
AMP VERSION - single axis Z
CABLE VERSION - dual axis XY - ±45°
ELECTRICAL CONNECTIONS
AMP VERSION - single axis Z
AMP Superseal 6 pole 282108-1 connector.
Mated with connector AMP 282090-1
CABLE VERSION - dual axis XY
6-wires output 18AWG 1.65 mm OD
© Danfoss | DCS (im) | 2019.04
DST X710
SINGLE/DUAL AXIS
ENTRY LEVEL
INCLINOMETER (XY/360°)
Danfoss A/S 6430 Nordborg Denmark
www.danfoss.com
WARNINGS AND SAFETY
Although all of the information in this manual has
been carefully checked, Danfoss A/S assumes no
liability regarding the presence of any errors or regarding
damage to property and/or harm to individuals due to any improper use
of this manual. Danfoss A/S also reserves the right to make changes to the
contents and form of this manual and to the characteristics of the devices
illustrated at any time and without prior warning.
The installation of the devices illustrated in the manual must be carried out by
qualified technicians in compliance with the laws and standards in force and
in agreement with the instructions contained in the manual.
The system should be only used in accordance with
the expected protection.
The sensor must be used in accordance with the environmental
features and performance of the instrument.
+0.5Vdc...+4.5 Vdc output with power +10...36Vdc and +0..10Vdc output
with power +11..36Vdc: it is recommended a load resistance > 100 KΩ
+0.5Vdc...+4.5 Vdc output with power +5 Vdc: it is recommended a load
resistance > 10 KΩ
+4...20 mA output with power < + 15..36Vdc: the maximum load resist-
ance is admissible 200Ω
+4...20 mA output with power > + 15..36Vdc: the maximum load resist-
ance is admissible 500Ω
CONNECTIONS
1. GROUND
2. + SUPPLY
MOUNTING
3. OUTPUT X
4. OUTPUT Y
5. n.c.
6. n.c.
CAN CONNECTIONS
1. GROUND
2. + SUPPLY
3. n.c.
4. n.c.
5. CAN-L
6. CAN-H
CONNECTIONS
Black: GROUND
Red: + SUPPLY
Yellow: OUTPUT X
Green: OUTPUT Y
Blue: n.c.
White: n.c.
CAN CONNECTIONS
Black: GROUND
Red: + SUPPLY
Yellow: n.c.
Green: n.c.
Blue: CAN-L
White: CAN-H
Mandatory use conical spring
washer
MA DIN 6796 A2 (3 pcs included)
LOAD CONDITIONS
Mount the sensor using M4 screws in nonmagnetic
stainless steel: eg AISI 316 or brass (not included).
It is mandatory to use conical spring washer M4 DIN 6796 A2
- 3 pcs (included)
Danfoss A/S with the "CE" mark are manufactured according with
the Community Directives and the related National Legislation
of concepition:
- 2004/108/CE (EMC Directive)
AN30144637278901-000101 | IC.PD.P20.CA.2Q | 1

Publicité

loading

Sommaire des Matières pour Danfoss DST X710

  • Page 1 Danfoss A/S also reserves the right to make changes to the CABLE VERSION - dual axis XY - ±45°...
  • Page 2 Danfoss A/S keinerlei Gewähr für die Fehlerfreiheit. Sie haftet auch nicht für Sach- oder Personenschäden aufgrund des zweckwidrigen Gebrauchs dieser Anleitung. Danfoss A/S behält sich das Recht vor, jederzeit und ohne Ankündigung Änderungen an Inhalt und Form dieses Dokuments KABELAUSGANG - zweiachsig XY - ±45°...
  • Page 3 être tenue pour responsable des erreurs éventuelles ou des dommages aux personnes ou aux biens dus à une utilisation impropre de ce manuel. Danfoss A/S se réserve en outre d’apporter, à tout moment et sans préavis, toute modification au contenu et à la forme de ce manuel ainsi qu’aux caractéristiques des dispositifs illustrés.
  • Page 4 Danfoss A/S si riserva inoltre il diritto di apportare modifiche al contenuto e VERSIONE CAVO - doppio asse XY alla forma di questo documento, come pure alle caratteristiche dei dispositivi illustrati, in qualsiasi momento e senza alcun avviso.