Installation guide
Single/Dual inclination sensor
DST X730
TILT DIRECTION
M12 VERSION - single axis Z
CABLE VERSION - dual axis XY
ELECTRICAL CONNECTIONS
M12 VERSION - single axiz Z
CONEC connector
M12 x 1 5 pole 43-01090
CABLE VERSION - dual axis XY
© Danfoss | DCS (im) | 2019.04
DST X730
TOP SINGLE/DUAL AXIS
INCLINOMETER (XY/360°)
Danfoss A/S 6430 Nordborg Denmark
www.danfoss.com
WARNINGS AND SAFETY
Although all of the information in this manual has
been carefully checked, Danfoss A/S assumes no
liability regarding the presence of any errors or regarding
damage to property and/or harm to individuals due to any improper use
of this manual. Danfoss A/S also reserves the right to make changes to the
contents and form of this manual and to the characteristics of the devices
illustrated at any time and without prior warning.
The installation of the devices illustrated in the manual must be carried out by
qualified technicians in compliance with the laws and standards in force and
in agreement with the instructions contained in the manual.
The system should be only used in accordance with
the expected protection.
The sensor must be used in accordance with the environmental
features and performance of the instrument.
+0.5VDC...+4.5 VDC output (powered at 10...36VDC) and 0...10 VDC out-
put (powered at +11...36 VDC): apply a load resistance > 100kΩ
+0.5 VDC...+4.5 VDC output ( powered at +5 VDC) maximum allowed
CONNECTIONS
load resistance is >10 kΩ
1. + SUPPLY
+4...20 mA output (powered at < +15..36 VDC) maximum allowed load
2. OUTPUT Y
resistance is 200Ω
3. GROUND
+4...20 mA output (powered at > +15..36 VDC) maximum allowed load
4. OUTPUT X
5. n.c.
resistance is 500Ω
CAN CONNECTIONS
MOUNTING
1. n.c
2. + SUPPLY
3. GROUND.
4. CAN-H.
5. CAN-L
CONNECTIONS
White: + SUPPLY
Yellow: GROUND
Grey: OUTPUT X
Electromagnetic compatibility according to Directive 2004/108/CE
Blue: OUTPUT Y
Vibrations 20g between 10Hz ... 2000 Hz EN 60068-2-6
Pink: n.c.
Shock pulse on 3 axes, 50g 11 ms EN 60068-2-27
Green: n.c.
Brown: n.c.
CAN CONNECTIONS
White: + SUPPLY
Yellow: GROUND
Grey: CAN-H
Blue: CAN-L
Pink: n.c.
Green: n.c.
Brown: n.c.
Mandatory use conical spring
washer
M5 DIN 6796 A2 (3 pcs included)
LOAD CONDITIONS
Mount the sensor using M5 screws in nonmagnetic stainless
steel: eg AISI 316 or brass (not included).
It is mandatory to use conical spring washer M5 DIN 6796 A2
- 3 pcs. (included).
ELECTROMAGNETIC COMPATIBILITY, VIBRATION, SHOCK –
REFERENCE STANDARD:
AN30144792979601-000101 | IC.PD.P20.EA.2Q | 1