Installation guide
Rotary sensor with shaft
DST X510
ROTATION DIRECTION
AMP VERSION
The output increases
for versions CCW
A
Ref
CW Output
A
0.5Vdc Output
Zero angular
B
position of 0 °
C
4.5Vdc Output
Ex: 098G1000
SINGLE- ± 90°- supply 7 - 36 V - output 0.5..4.5V - clockwise CW
Vout= 2.5V
Angular position 0°
ELECTRICAL CONNECTIONS
AMP VERSION
AMP Superseal 6-pole 282108-1
connector. Coupled with AMP 282090-1
2
0
-
0
18
-
DEUTSCH VERSION
DEUTSCH 6 pole DT04-6P Connector
Coupled with connector DEUTSCH
DT06-6S
+
2
0
0
-
0
18
-
To ensure the degree of protection IP68 the connector must be coupled
with DEUTSCH DT06-6S female connector.
© Danfoss | DCS (im) | 2019.09
DEUTSCH VERSION
Zero angular
The output increases
position of 0 °
for versions CW
A
CCW Output
4.5Vdc Output
Zero angular
position of 0 °
0.5Vdc Output
Vout= 4.5V
Angular position 90°
CONNECTIONS
1. GROUND 1
2. + SUPPLY 1
3. OUTPUT 1
4. GROUND 2
5. + SUPPLY 2
6. OUTPUT 2
CAN CONNECTIONS
1. OV (GND)
2. +Vs (+9 ... +36 Vdc)
3. NC
+
0
4. NC
5. CAN-L
6. CAN-H
CONNECTIONS
1. GROUND 1
2. + SUPPLY 1
3. OUTPUT 1
4. GROUND 2
5. + SUPPLY 2
6. OUTPUT 2
CAN CONNECTIONS
1. OV (GND)
2. +Vs (+9 ... +36 Vdc)
3. NC
4. NC
5. CAN-L
6. CAN-H
DST X510
HALL-EFFECT SIGLE-TURN
ROTARY SENSOR WITH
SHAFT
Danfoss A/S 6430 Nordborg Denmark
www.danfoss.com
WARNINGS AND SAFETY
Although all of the information in this manual has been carefully checked,
Danfoss A/S assumes no liability regarding the presence of any errors or
regarding damage to property and/or harm to individuals due to any
improper use of this manual.
Danfoss A/S also reserves the right to make changes to the contents and
form of this manual and to the characteristics of the devices illustrated at
any time and without prior warning.
The installation of the devices illustrated in the manual must be carried out
by qualified technicians in compliance with the laws and standards in force
and in agreement with the instructions contained in the manual.
The system should be only used in accordance with
the expected protection.
The sensor must be used in accordance with the environmental
features and performance of the instrument.
LOAD CONDITIONS
Output: +0.5 vdc...+4.5 Vdc with +5 Vdc power supply: apply load re-
sistance >10 kΩ
Output: +0.5 VDC...+4.5 Vdc with +5 Vdc power supply: apply load
resistance >10 kΩ
Outputs: +4...20 mA with < + 15..36Vdc power supply: maximum
allowed load resistance is 200Ω Outputs +4...20 mA with > + 15..36Vdc
power supply: maximum allowed load resistance is 500Ω
Danfoss A/S with the "CE" mark are manufactured
according with the Community Directives and the related
National Legislation of concepition:
- 2011/65/EU Restriction of the use of certain hazardous
substances (RoHS)
- 2014/30/EU Electromagnetic Compatibility (EMC)
- 2001/95/EC General product safety
MOUNTING
Mount the sensor using M4 screws in nonmagnetic
stainless steel: eg AISI 316 or brass (not included).
The maximum torque amounts to 2.5Nm.
AN301444192787en-000201 | IC.PD.P20.AB.2Q | 1