active anode also protects the steel
plate against corrosion.
The specially fired enamel design
provides long life in case of aggressive
(soft)
water.
dimensions of the water storage are
described in Figure 1.
The horizontal placement of the
unit permits installation in locations
where vertical placement of the unit
would not be possible due to height
limitations.
3. STORAGE INSTALLATION /
DEPLOYMENT
Pursuant to regulations of Hungarian
Standards MSZ 2364 / MSZ HD 60364,
the hot water storage must be installed
and
connected
electricity by a professional technician.
Before installation of the unit, a
professional architect has to analyze
the structure of the wall where the
unit will be mounted.
The following solutions are proposed in
case of different wall types:
• Stone, brick and concrete walls
of thickness of 100-150 mm: hex head
bolts (Hungarian Standard M 12, MSZ
EN ISO 4017), bolt washer for wood
connection (M 12). It is mounted with
horizontal flat steel of 50 x 5 at the
back side of the wall.
• Really thin walls: hex head bolts
(Hungarian Standard M 12, MSZ EN ISO
4017),
bolt
connection (M 12). Fixed with 2 U
shaped steels of 60 x 40 x 3 (MSZ EN
10279) vertically at the back side of
the wall.
In
case
horizontal water tanks, an installation
All manuals and user guides at all-guides.com
The
main
outline
to
pipeline
washer
for
of
wall
mountable
EN
distance of at least 70 cm has to be
guaranteed on the side of the fitting
area.
Wall mountable horizontal hot water
tanks
adjusted "left design", mounted
ready (see Figure 1)
Check
suspension legs. If this installation
placement is suitable, then there is
nothing left to do, except for
mounting the unit on the bolts fixed
on the wall and fix the unit with
bolt washers, bolt nuts. Before
mounting
tension of the mounting bands, and
tighten the screws fixing the bands
placed on the front of the hot water
tank, if necessary.
and
If the distance between the screws
fixed in the wall and the distance of
suspension legs fixed to the unit are
different, then the followings should
be done:
1. Loosen the screws fixing the
bands (placed on the front of the
hot water tank) and set the bands
together with the suspension legs
either closer or farther. Take care
that the supporting plate under the
suspension legs should remain under
the suspension legs in this new
placement, as well.
2. Tighten the screws and lay the
hot water tank on a floor being in
the same plane as the suspension
wood
legs.
3. Check that the suspension legs
remain in the same plane. If you
perceive a different case, then
loosen one of the screws. If the
suspension legs have moved in the
12
are
delivered
the
placement
the
unit,