Setting Maintenance Cycles; Motor Maintenance - AERTECNICA Tubo CMT800 Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SETTING MAINTENANCE CYCLES

In LM or LM MASTER mode, the Dynamic Control
Display can be used to customise the threshold relative
to dust container and filter cartridge maintenance based
on the actual use of the installed central power unit.
SETTING THE DUST CONTAINER MAINTENANCE
THRESHOLD
In STAND BY mode, press the PROG/RESET key for 10
seconds.
INFORMAZIONI
REGISTRI
INFORMAZIONI
SOGLIA SACCO
SOGLIA FILTRO
X
RESET
The SERVICE menu will appear.
Select SOGLIA SACCO and press MENÙ/ENTER to
confirm.
SOGLIA ALLARME
X
RESET
The SOGLIA ALLARME parameter will appear, expressed
in hours (the default setting is 8 hours).
Use the arrows to change this parameter.
Press MENÙ/ENTER to confirm.
To exit the SERVICE menu, press the PROG/RESET key;
the STAND BY screen will appear on the display.
SETTING THE fILTER MAINTENANCE THRESHOLD
In STAND BY mode, press the PROG/RESET key for 10
seconds.
INFORMAZIONI
REGISTRI
INFORMAZIONI
SOGLIA SACCO
SOGLIA FILTRO
X
RESET
The SERVICE menu will appear.
Select SOGLIA FILTRO and press MENÙ/ENTER to
confirm.
V
ENTER
8
V
ENTER
V
ENTER
SOGLIA ALLARME
X
RESET
The SOGLIA ALLARME parameter will appear, expressed
in hours (the default setting is 12 hours).
Use the arrows to change this parameter.
Press MENÙ/ENTER to confirm.
To exit the SERVICE menu, press the PROG/RESET key;
the STAND BY screen will appear on the display.

MOTOR MAINTENANCE

In LM or LM MASTER mode, the Dynamic Control
Display can be used to reset the counter relative to the
effective hours of motor operation if replaced.
MOTOR RESET SETTING
In STAND BY mode, press the PROG/RESET key for 10
seconds.
The SERVICE menu will appear.
MODELLO
CONTRASTO LCD
INFORMAZIONI
REGISTRI
RESET MOTORE
X
RESET
Select RESET MOTORE
Press MENÙ/ENTER to confirm.
The RESET ORE MOTORE parameter will appear that
displays the total hours of operation of both the central
power unit and the motor in use.
RESET ORE MOTORE
TOT
MOT
X
RESET
To reset motor hours, press the
PROG/RESET key for a few seconds: the hours of motor
operation parameter will reset.
To exit the RESET ORE MOTORE menu mode, press
MENÙ/ENTER and then PROG/RESET.
10
12
V
ENTER
V
ENTER
400
200
V
ENTER
LM mode

Publicité

Table des Matières
loading

Table des Matières