CONfIGURATION IN MODBUS MODE
The Dynamic Control Display CMT800 is set by
AERTECNICA to MODBUS mode.
With this configuration (protocol RS485ModBus) it
communicates directly with all PERFETTO INOX TXA, TPA,
TP and CLASSIC TC central power unit models.
To reset the Dynamic Control Display to ModBus mode,
power the device.
The central power unit's STAND BY screen will appear.
Hold down the PROG/RESET key for 10 seconds.
The SERVICE menu will appear.
MODELLO
CONTRASTO LCD
INFORMAZIONI
REGISTRI
RESET MOTORE
X
RESET
Select MODELLO
Press MENÙ/ENTER to confirm.
The SELEZ MODELLO menu will appear
SELEZ. MODELLO
MODBUS
TR BUS
LM
LM MASTER
X
RESET
Select MODBUS
Press MENÙ/ENTER to confirm.
The Dynamic is now configured in MODBUS mode.
To exit the SERVICE menu, press the PROG/RESET key;
the STAND BY screen will appear on the display.
V
ENTER
V
ENTER
3
MODBUS mode
The message ANOMALIA NO RETE will appear on the
display check the electrical connection.
ANOMALIA
NO RETE

MOTOR MAINTENANCE

The hour counter relative to the effective hours of
motor operation can be reset in MODBUS mode.
MOTOR RESET SETTING
In STAND BY mode, press the PROG/RESET key for 10
seconds.
The SERVICE menu will appear.
MODELLO
CONTRASTO LCD
INFORMAZIONI
REGISTRI
RESET MOTORE
X
RESET
Select RESET MOTORE
Press MENÙ/ENTER to confirm.
The RESET ORE MOTORE parameter will appear that
displays the total hours of operation of both the central
power unit and the motor in use.
RESET ORE MOTORE
TOT
MOT
X
RESET
To reset the motor hours press the
PROG/RESET key for a few seconds: the parameter for
motor operating hours will reset.
To exit the RESET ORE MOTORE menu mode, press
MENÙ/ENTER and then PROG/RESET.