Attention! The fitting must be installed,
flushed and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer
in position on the basin.
3. Slip the fixation piece including the washer
over the threaded pin and tighten the nut.
4. If necessary shorten platic hose according to
the table and insert it up to the collar into the
shorter blue marked copper pipe.
5. Connect the shorter, blue marked supply pipe
to the angle valve.
Connect the longer blue marked pipe to the
inlet and the red marked to the outlet of the
storage tank.
6. Connect the pull rod to the pop-up waste.
Attention!*
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min.
In this case the flow rate must be reduced at the
isolation valve.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
max. permissible water pres-
sure on the spot
in bars
1 - 1,5
2 - 3
4 - 7
6
Hose lengths to be used
8, 10 and 15 liters
without hose
hose to be short
If pressure greater than 5 bar, fit pressure reducer.
English
When the storage tank is being heated, the spout
will drip.
When changing the spray former, it is imperative
to use one made for this type of mixer.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow with water heaters
of 5 liters:
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
flange gold plated
3
nut
4
cartridge cpl.
5
spray former
spray former gold plated
6
pop up rod
7
fixing set
storage tank volume
ened to 90 mm
hose unchanged,
reduce flow rate at the angle valve*
up to 5 liters
hose to be shortened to 90 mm
hose unchanged
max. 10 bars
1 - 5 bars
16 bars
max. 80° C
65° C
max. 5 l/mint
14094000
96338000
96656000
96656990
96690000
92730000
94033000
94033990
96657000
96016000