Continuous Drainage; Maintenance / Cleaning - Bionaire BD2425-CN Guide D'utilisation

Déshumidificateur numérique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

F E AT U R E S - O P E R AT I O N S
C L E A N I N G / M A I N T E N A N C E
Temperature
When sensor detected ambient temperature is equals/
below 0ºC or equals/above 40ºC, warning beeps with 3
long and 2 short signals will activate in order to protect
the unit from shutting off automatically.
1. All function keys are out of functions, you should
unplug to restart the unit.
2. Any abnormal over heating of greater than 40ºC
inside the unit, the unit will shut off as well.
Failures Of Humidity & Temperature Sensor
1. When the connect wire of humidity and temperature
sensor break off, the "Stay On" indicator light will
blink, the unit comes into continuous dehumidifying
mode, it can work after obviating the failure.
2. When the temperature sensor of evaporator appears
open circuit or short circuit, the defrosting indicator
light will blink, the unit turns into settled
dehumidifying and defrosting mode: dehumidifying
for 20 minutes, then defrosting for 5 minutes.

Continuous Drainage

Remove water plug and connect with PVC hose with
spigot.
1. PVC hose must be placed on the ground flatly.
2. Do not tangle the hose.
3. Do not immerse the end of water outlet into other
receptacle to avoid water flow blocked.
MAINTENANCE & CLEANING
1. Before any maintenance or cleaning, please switch
off and unplug the unit.
2. For its casing is made of wood and plastic, do not
place it in direct sunlight.
3. Remove the water reservoir with care.
4. If not using the unit for a long time. Please switch off
and unplug the unit, empty the water reservoir, and
pack it after 2 days, then, keep it in dry and
ventilated place.
5. Only use a soft clean cloth for all cleaning purpose.
Do not use gasoline, paint thinner or other chemicals
to clean the unit.
6. Cleaning mesh filter: To remove the filter in arrow
direction (See Figure 5). Use a vacuum cleaner or
water to clean, then put it in ventilated place until it's
dry.
Figure 4
Figure 5
Air Filter
Air Intake Frame

Publicité

Table des Matières
loading

Table des Matières