Installation Niche Features: X-Pro Series - Fhiaba 599 Serie Notice D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
Minimum Niche Height
2134 (84)
Minimum Niche Width
XG899: 900 mm (35 3/8 in)
XG749: 750 mm (29 1/2 in)
XG599: 600 mm (23 5/8 in)
Door Swing Clearance
XG899: 1498 mm (58 63/64 in)
XG749: 1320 mm (51 31/32 in)
XG599: 1292 mm (50 7/8 in)
140 (5 ½)
A
XG899: 900 (35 3⁄ 8 )
XG749: 750 (29 ½)
XG599: 600 (23 5⁄ 8 )
XG899: 887 (35)
XG749: 737 (29)
XG599: 587 (23 1⁄ 8 )
All manuals and user guides at all-guides.com
140 (5 ½)
A
E
W
700 (27 ½)
625 (24 5⁄ 8 )
758 (29
7⁄ 8
)
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161

Installation niche features: X-Pro Series

Door Opening Angle
105°
Width
XG899: 887 mm (35 in)
XG749: 737 mm (29 in)
XG599: 587 mm (23 1/8 in)
Height
2134 mm (84 in) ± 12,7mm (1/2 in)
Depth with door
700 mm (27 1/2 in)
XG899: 899 (35)
XG749: 749 (29 ½)
XG599: 599 (23 5⁄ 8 )
IMPORTANT
Flush
Installation Guide
XG899: 138 (5 3⁄ 8 )
XG749: 112 (4 3⁄ 8 )
XG599: 86 (3 3⁄ 8 )
7