Installation Step by Step

TOOLS REQUIRED

• Phillips #2 or Robertson #1 screwdriver
• 3/32" drill bit
• Tin snips or metal shear
• Power Drill
LOCATION
Return side connections is to be installed after the
last branch on the return air plenum and minimum
2 linear ft distance from furnace.
A 5-ft power cord is supplied with the unit. If not
available a 120VAC outlet needs to be supplied.
Note to installer
Refer
to
the
general
information section for details on how
to remove the unit's door and filters.
Tips to installer
Please consult local authorities to find
out whether the installation of electrical
products requires the services of
a certified technician or electrician.
Removing the filters from the unit will
facilitate your job.
DUCTING FLAIRS
MOUNTING SYSTEM
The Whole-House HEPA Plenum Systems are de-
signed for single person installation.
Once the holes are made in the main return duct
and the unit is aligned, the installer just has to
unfold the «Ducting Flairs» and screw the unit in
place.
Tips to installer
It is recommended that the filtration unit
have a devoted receptacle with 120V.
It is not recommended to connect unit
with an extension cord. If no receptacle
is available please call an electrical con-
tractor to have one installed.
fantech
STEP BY STEP INSTALLATION
Steps involved in the preparation of the plenum mount system are as followed:
Step 1
Preparing return air plenum
Find a location that satisfies both service and maintenance requirements and proceed to cut holes as
illustrated below.
THIS LINE MUST BE LEVEL / CETTE LIGNE DOIT ÊTRE AU NIVEAU
Drill Hole (3/32")
Drill Hole (3/32")
Drill Hole (3/32")
Percer un trou
Percer un trou
Percer un trou
Drill Hole (3/32")
Percer un trou
3.5"
16"
Drill Hole (3/32")
Drill Hole (3/32")
Drill Hole (3/32")
Percer un trou
Percer un trou
Percer un trou
ATTENTION
Cut
CUT THE EDGES SHOWN ONLY
COUPER LES SURFACES INDIQUÉS SEULEMENT
Drill Hole (3/32")
Percer un trou
Drill Hole (3/32")
Drill Hole (3/32")
Drill Hole (3/32")
Percer un trou
Percer un trou
Percer un trou
3.5"
16"
Drill Hole (3/32")
Drill Hole (3/32")
Drill Hole (3/32")
Percer un trou
Percer un trou
Percer un trou
Tape template to return air plenum. Cut opening with metal shears, predrill for the securing screws
and remove template.
operation
Step 2
Preparing ducting flairs
Remove the door and filters and proceed to cut the insulation as illustrated below.
Cut the insulation along the in-
side edge of both inlet and out-
let ports to remove the insula-
tion from the port openings.
Cut the four metal tabs to release the mounting flairs for the inlet and outlet ports.
Apply plenum seal tape all around both openings on the back of the unit. Bend tabs outward approxi-
mately 90 degrees.
Step 3
Mount Hepa
Align unit into place. Unfold the ducting flairs completly to sandwich the return air plenum between the
ducting flair and the filtration unit. Install unit as usual using all supplied fastening hardware.
Drill Hole (3/32")
Percer un trou
Drill Hole (3/32")
Percer un trou
One cut permits the clean re-
moval of the insulation piece.
The unit should look like this
when the foam piece is rem-
vouved.