Installation Examples; Fully Dedicated System - Fantech SHR Serie Manuel D'installation

Masquer les pouces Voir aussi pour SHR Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation examples

FULLY DEDICATED SYSTEM

BEST FOR NEW CONSTRUCTION
Stale air is drawn from key areas of home (bathroom, kitchen, laundry)
Fresh air supplied to main living areas
1. Weatherhood arrangement is for illustrative purposes only. 3m (10')
minimum separation and 460 mm (18") above grade is recommended.
2. The HRV's airflow must be balanced on site, using the procedure found in
section "AIRFLOW BALANCING".
* Ductwork layout may dif-
fer depending on model
Fresh air from
outside
Stale air to
outside
* Unit air flow should be balanced while HRV is on "Normal" speed and
furnace blower is running.
Suggested installation for:
• Hydronic baseboard
• Infloor heating
• Electric baseboard
• Mini split heat pump
Benefits: Provides the best
fresh air distribution in the
house; lowest operation cost
since the furnace/air handler
unit is not needed.
Air from inside
Fresh air to
living areas
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Vhr serieShr 2004Shr 2005rShr 3005rShr 3205rdVhr 2004

Table des Matières