Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

Location

The HRV must be located in a conditioned space where it will be possible to conveniently service the unit. Typically the HRV would be located in the
mechanical room, above a drop ceiling or an area close to the outside wall where the weatherhoods will be mounted. Attic installations are not recom-
mended due to extreme temperatures, and difficulty in performing, required service & maintenance. Care must be taken to locate the recirculation port in
an area that will not cause any unwanted contaminant to be drawn into the living space during recirculation and defrost.
Flexible duct connectors should be installed between the HRV and the galvanized ductwork.
Connecting appliances to the HRV It is not recommended, including:
• clothes dryer
• kitchen exhaust hoods
• combustion venting
• central vacuum system
These appliance may cause lint, dust or grease to collect in the HRV , damaging the unit.
Connecting any of these type of appliances to the HRV will invalidate your warranty
Model
A
Kg
SHR 8005R
23.8
SHR 14105R
30.4
B
C
lbs
Kg
lbs
in.
52.5
22.5
49.6
15.4
67
27
60
21.4
A
D
E
mm.
Kg
lbs
Kg
390
85
187
20
544
109
241
27.7
B
F
D
E
G
C
F
G
lbs
Kg
lbs
in.
44
18.8
41.3
17.6
61
24.3
53.5
18
5
mm.
448
455
fantech

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Shr 14105r422466

Table des Matières