NOTE: Little maintenance is required, but
regular cleaning of the brush, brush tank,
cutter mechanism and tape path are
important. Clean the tape dispenser when the
water bottle needs refilling.
CAUTION! Before performing any maintenance
or repair procedures, turn off power switch and
disconnect from power source.
CLEANING WATER FEED SYSTEM
1. Clean the brush by soaking in warm, soapy water.
Rinse with warm water.
2. Clean the brush tank by rinsing in warm water.
3. Rinse out the water bottle and duckbill valve with
warm water.
CLEANING CUTTER ASSEMBLY
1. Open top cover and remove pressure plate.
2. Remove tape from tape path.
3. Using a small amount of non-flammable lubricant,
spray the cutter assembly behind the cutter guard
through the gaps in front and behind the cutter
guard.
4. Place tape back in tape path and place pressure
plate back into the machine.
Before performing any maintenance or repair procedures, turn off power
switch and disconnect from power source.
PROBLEM
Machine will not
dispense tape.
Tape is jamming,
rearing or won't feed.
PAGE 4 OF 15
MAINTENANCE
TROUBLESHOOTING
CAUSE
Dispenser is not plugged in.
Power switch is in the OFF position.
Display is flashing in program mode.
Debris is in the tape path.
Tape guides are too tight.
Tape is routed incorrectly.
Pressure plate is out of place.
Too much weight on the brush.
Cutter is not cutting tape.
CLEANING TAPE PATH
1. Open top cover and remove pressure plate.
2. Remove tape from tape path.
3. Using compressed air, remove all debris from the
tape path.
4. To remove gum adhesive buildup, use a moist cloth
to wipe down all sheet metal parts within tape
path. This includes the tape channel, pressure plate,
weighted brush tank cover and water tank holder.
5. Place the tape back into the tape path and place
the pressure plate back in the machine.
6. Close the top cover.
SOLUTION
Plug power cord into outlet.
Turn power switch to ON position.
Press program key to turn off program mode or finish
program cycle or turn power OFF and ON.
Clean the tape path.
Adjust the tape guides with the tape guide turnbuckle.
Reroute the tape.
Verify the pressure plate is in place.
Adjust the amount of weight on the brush.
Clean the cutter assembly. If problem persists, contact