Operating instructions
9
Maintenance and repair
EN
8.3
Removing the access door
The access door of the heated well can be removed without tools for
cleaning.
►
Open the access door about half way.
►
Pull the access door forward out of its anchoring.
DANGER
Electrical hazard
Electricity is a serious hazard and can cause injury or even death.
►
Only qualified electricians may carry out work on electrical
components.
►
Disconnect the appliance from the mains.
►
Secure the appliance against being switched on again.
WARNING
Hot surface
The stainless steel surfaces of the heated wells are hot after
operation. Touching them can lead to burns.
►
Let the appliance cool down sufficiently before cleaning.
9.1
Maintenance
The following components should be checked at regular intervals for
functionality:
Leaktightness of the silicone joints in the heated well
ThermaDry heated well