1. When reinstalling the blower into the hood, you will have to mount the blower in
the same direction you have ducted it (horizontal, vertical or ductless).
2. Using the 4 nuts removed earlier, secure the blower in place. Start the nuts by
hand first, then tighten with a 3/8" nut driver or ratchet. A 3/8" ratchet with an
extension will make this operation easier.
3. Plug the blower into the appropriate connector on the side of the wire
compartment.
Note: For ductless installation, remove the range hood's vent insert from the front
grille.
Preparation for Duct Connection
1. Remove the appropriate ducting knockout by inserting a screwdriver under one
end and prying it up. Then snip or break the attachment points.
2. Install the damper assembly to the range hood with the 2 screws supplied (fig. 2).
3. If discharge is vertical through a rectangular duct, remove the knockout sections
D, B and E only (Fig. 4).
4. If the vertical discharge is through a 7" round duct, remove knockout sections
"A" and "B" and "C" only (Fig. 4).
Note: Section "D" and "E" remain with the hood.
5. Mount the round collar (E22A -not supplied) over the opening on the hood by
using 3 shorter screws. Allow the bottom edge of the 7" duct to be inserted into
the collar.