Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The
accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than
75%, non-condensing.
V/DC
Range
200 mV
2 V
20 V
200 V
600 V
Overload protection: 600 V; impedance >7.5 MΩ
Alternating voltage V/AC
Range
2 V
20 V
200 V
600 V
Frequency range 50 – 60 Hz; average value with sinus voltage; overload protection 600 V; impedance >7.5 MΩ
Resistance Ω
Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Overload protection 600 V
Diode test
Test voltage
1.5 V
Overload protection 600 V
Acoustic continuity tester
Do not exceed the maximum permitted input values. Do not contact circuits or parts
of circuits if there could be voltages higher than 25 V ACrms or 35 V DC present wit-
hin them. Mortal danger!
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0,01 MΩ
Resolution
0.001 V
<35 Ω permanent sound, overload protection 600 V
Accuracy
±(0.8% + 4)
±(1.3% + 4)
Accuracy
±(1.3% + 6)
±(1.8% + 10)
Accuracy
±(1.0% + 6)
±(1.5% + 4)
±(2.0% + 5)
±(5.0% + 8)
Test current
1 mA (typical)
37